What was found
INT - DURING 'Q-1' CHECK VISUAL INSPECTION, FOUND 4 AREAS 1 INCH BY 1 INCH CORRODED AREAS FLOOR BEAM BS 947, LBL 4 - RBL 11. INSTALLED T-CAP AND REPAIR ANGLES. REPAIRED PER SRM 53-00-051 AND EA 40947. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-1' CHECK VISUAL INSPECTION, FOUND 4 AREAS 1 INCH BY 1 INCH CORRODED AREAS FLOOR BEAM BS 947, LBL 4 - RBL 11. INSTALLED T-CAP AND REPAIR ANGLES. REPAIRED PER SRM 53-00-051 AND EA 40947. (X)