What was found
INT - DURING 'Q-1' CHECK VISUAL INSPECTION, FOUND .75 INCH CORROSION FLOOR BEAM BS 967, RBL 42. CUT OUT CORRODED AREA, FABRICATED AND INSTALLED REPAIR ANGLES AND FILLER. REPAIRED PER SRM 53-60-51, FIGURE 203. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-1' CHECK VISUAL INSPECTION, FOUND .75 INCH CORROSION FLOOR BEAM BS 967, RBL 42. CUT OUT CORRODED AREA, FABRICATED AND INSTALLED REPAIR ANGLES AND FILLER. REPAIRED PER SRM 53-60-51, FIGURE 203. (X)