What was found
CLT - INSPECTION VISUALLY FOUND LEVEL 1 CORROSION AROUND SCREW HOLES 30 INCH LENGTH ON TOP OF BEAM LOCATED AT STA 344 - 181 BL TO 12 RBL. CUT CORRODED BEAM T-CAP OFF AND REPLACED PER BOEING SRM 53-10-51. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION VISUALLY FOUND LEVEL 1 CORROSION AROUND SCREW HOLES 30 INCH LENGTH ON TOP OF BEAM LOCATED AT STA 344 - 181 BL TO 12 RBL. CUT CORRODED BEAM T-CAP OFF AND REPLACED PER BOEING SRM 53-10-51. (X)