What was found
PIT - DURING Q-4/C-6 INSPECTION, FOUND TWO 2 INCH CRACKS IN CUSP MEMBRANE STATION 617 RIGHT SIDE. REPLACED SECTION OF CUSP MEMBRANE FROM STATION 598 TO 637 PER SRM 53-05 FIG 97. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4/C-6 INSPECTION, FOUND TWO 2 INCH CRACKS IN CUSP MEMBRANE STATION 617 RIGHT SIDE. REPLACED SECTION OF CUSP MEMBRANE FROM STATION 598 TO 637 PER SRM 53-05 FIG 97. (M)