What was found
PIT - DURING Q-4/C-6 INSPECTION, FOUND .25 INCH CRACKS AT FASTENER HOLES LONGERON 23L STATION 180 AND STATION 200. SPLICED IN SECTION OF LONGERON FROM STATION 160 TO STATION 230 PER SRM 53-02 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4/C-6 INSPECTION, FOUND .25 INCH CRACKS AT FASTENER HOLES LONGERON 23L STATION 180 AND STATION 200. SPLICED IN SECTION OF LONGERON FROM STATION 160 TO STATION 230 PER SRM 53-02 FIG 2. (M)