What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH CORRODED AREA STRINGER 26R BS 520-540. INSTALLED STRINGER REPAIR, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH CORRODED AREA STRINGER 26R BS 520-540. INSTALLED STRINGER REPAIR, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)