What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION IN STRINGER (APPROX 3 INCHES LONG) STRINGER 26L AT STATION 966. INSTALLED STRINGER REPAIR, REPAIRED PER SRM 53-10-3 FIG 1. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION IN STRINGER (APPROX 3 INCHES LONG) STRINGER 26L AT STATION 966. INSTALLED STRINGER REPAIR, REPAIRED PER SRM 53-10-3 FIG 1. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)