What was found
DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA ON FRAME AT BS 500 STRINGER 26R. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-3. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA ON FRAME AT BS 500 STRINGER 26R. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-3. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)