What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK STABILIZER STRAP (BOTTOM OF FLOOR BEAM) BS 312, RBL 45. INSTALLED DOUBLER, REPAIRED PER SRM 53-10-9. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK STABILIZER STRAP (BOTTOM OF FLOOR BEAM) BS 312, RBL 45. INSTALLED DOUBLER, REPAIRED PER SRM 53-10-9. (M)