What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .25 CRACK STRINGER TIE CLIP STATION 360, STRINGER 4L. FABRICATED AND INSTALLED NEW TIE CLIP, REPAIRED PER SRM 57-10-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .25 CRACK STRINGER TIE CLIP STATION 360, STRINGER 4L. FABRICATED AND INSTALLED NEW TIE CLIP, REPAIRED PER SRM 57-10-1. (M)