What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CRACK 1 INCH LONG STATION 350 AT STRINGER 17L FRAME. REMOVED DAMAGED AREA FABRICATED REPAIR AND REPAIRED PER SRM 20-30-06 SRM 51-40-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CRACK 1 INCH LONG STATION 350 AT STRINGER 17L FRAME. REMOVED DAMAGED AREA FABRICATED REPAIR AND REPAIRED PER SRM 20-30-06 SRM 51-40-4. (M)