What was found
PIT - DURING A SCHEDULED Q-1/C-1 CHECK INSPECTION, FOUND STATION 1380 FORWARD SIDE FRAME CHAFED BETWEEN LONGERON 4L AND 5L. ROUTED OUT CHAFED AREA AND INSTALLED DOUBLER REPAIR PER SRM 53-01 FIG 2 SHEET 3 AND SRM 53-14-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING A SCHEDULED Q-1/C-1 CHECK INSPECTION, FOUND STATION 1380 FORWARD SIDE FRAME CHAFED BETWEEN LONGERON 4L AND 5L. ROUTED OUT CHAFED AREA AND INSTALLED DOUBLER REPAIR PER SRM 53-01 FIG 2 SHEET 3 AND SRM 53-14-1. (M)