What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 10 INCH BY 3 INCH CORROSION BS 1006 TO BS 996 STRINGER 26L. INSTALLED REPLACEMENT STRINGER SECTION, REPAIRED PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 10 INCH BY 3 INCH CORROSION BS 1006 TO BS 996 STRINGER 26L. INSTALLED REPLACEMENT STRINGER SECTION, REPAIRED PER SRM 53-10-3. (M)