What was found
PIT - DURING Q-5/C5 CHECK INSPECTION, FOUND 2 INCH BY 3 INCH LEVEL 1 CORRODED AREA PREVIOUSLY REWORKED IN BELTFRAME STATION 1309 LONGERON 30. CORROSION TASK NR C57-53300. ACCOMPLISHED SPLICE REPAIR PER SRM 53-03 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-5/C5 CHECK INSPECTION, FOUND 2 INCH BY 3 INCH LEVEL 1 CORRODED AREA PREVIOUSLY REWORKED IN BELTFRAME STATION 1309 LONGERON 30. CORROSION TASK NR C57-53300. ACCOMPLISHED SPLICE REPAIR PER SRM 53-03 FIG 2. (M)