As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING Q-5/C5 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AREA 4 INCHES BY 4 INCHES AT STATIC PORT HEATING PAD SKIN BETWEEN STATION 446 AND 465 BETWEEN LONGERON 26L AND 27L. CORROSION TASK REF C51-53300. REMOVED DAMAGED AREA AND SPLICED IN NEW SKIN SECTION PER USAIR EA NR 32634. (M)