What was found
PIT - DURING C-1 CHECK INSPECTION, FOUND .5 INCH LONG CRACK IN LONGERON 3L AT STATION 756. INSTALLED SPLICE REPAIR PER SRM 53-02 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-1 CHECK INSPECTION, FOUND .5 INCH LONG CRACK IN LONGERON 3L AT STATION 756. INSTALLED SPLICE REPAIR PER SRM 53-02 FIG 2. (M)