What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 10 INCH CORRODED AREA STRINGER 27L BS 948. CUT OUT CORRODED SECTION OF STRINGER FABRICATED NEW SECTION AND SPLICED BACK IN, REPAIRED PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 10 INCH CORRODED AREA STRINGER 27L BS 948. CUT OUT CORRODED SECTION OF STRINGER FABRICATED NEW SECTION AND SPLICED BACK IN, REPAIRED PER SRM 53-10-3. (M)