What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 9 INCH CORRODED AREA AFT CARGO BS 967-987 STRINGER 25L. INSTALLED STRINGER SPLICE AND REPAIRED PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 9 INCH CORRODED AREA AFT CARGO BS 967-987 STRINGER 25L. INSTALLED STRINGER SPLICE AND REPAIRED PER SRM 53-10-3. (M)