What was found
INT - DURING 'Q-6' CHECK VISUAL INSPECTION FOUND 3 CRACKS, 1 INCH, 1 INCH, AND .50 INCH, 178 BULKHEAD. STOP DRILL CRACKS, FABRICATED DOUBLER, FILLERS, AND INSTALLED. REPAIRED PER SRM 51-10-1, TR 53-10-11. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-6' CHECK VISUAL INSPECTION FOUND 3 CRACKS, 1 INCH, 1 INCH, AND .50 INCH, 178 BULKHEAD. STOP DRILL CRACKS, FABRICATED DOUBLER, FILLERS, AND INSTALLED. REPAIRED PER SRM 51-10-1, TR 53-10-11. (X)