As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH CORRODED SCREW HOLES ON FLOOR BEAM BS 328 22 INCHES RBL 36 INCHES RBL AND 42 INCHES RBL. REPLACED SECTION OF FLOOR BEAM AND INSTALLED ANGLES. REPAIRED PER TR 53-10-13. (X)