What was found
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 5 INCH BY 3 INCH CORRODED AREA STR 27L BS 967 TO BS 972. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3, FIGURE 1. CORROSION TASK NR: C53-208-01. CORROSION LEVEL: 2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 5 INCH BY 3 INCH CORRODED AREA STR 27L BS 967 TO BS 972. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3, FIGURE 1. CORROSION TASK NR: C53-208-01. CORROSION LEVEL: 2. (X)