What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER AREAS OF CORROSION STATION 986.5 FLOOR BEAM UPPER CHORD LBL 45 TO RBL 45, WL 208. REPAIRED PER EA 41219. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER AREAS OF CORROSION STATION 986.5 FLOOR BEAM UPPER CHORD LBL 45 TO RBL 45, WL 208. REPAIRED PER EA 41219. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)