What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES BS 312 RBL 8 THROUGH LBL 8. INSTALLED NEW SECTION OF UPPER CHORD, REPAIRED PER SRM 53-10-51 FIG 205. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES BS 312 RBL 8 THROUGH LBL 8. INSTALLED NEW SECTION OF UPPER CHORD, REPAIRED PER SRM 53-10-51 FIG 205. (M)