PIT - DURING AFT PRESSURE BULKHEAD REPAIR, PCI-919, FOUND CRACK APPROXIMATELY .5 INCH LONG ON CANTED FRAME STA 1104, STR 12R. INSTALLED DOUBLER 2024T3, .063 INCH PER SRM 53-03, FIG 30. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING AFT PRESSURE BULKHEAD REPAIR, PCI-919, FOUND CRACK APPROXIMATELY .5 INCH LONG ON CANTED FRAME STA 1104, STR 12R. INSTALLED DOUBLER 2024T3, .063 INCH PER SRM 53-03, FIG 30. (X)