What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCHCORRODED AREA FLOOR BEAM BS 360 RBL 54. INSTALLED REPAIR ANGLE, REPAIREDPER TR 53-10-05 C. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1.(M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCHCORRODED AREA FLOOR BEAM BS 360 RBL 54. INSTALLED REPAIR ANGLE, REPAIREDPER TR 53-10-05 C. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1.(M)