What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND TWO 1 INCH BY 3INCH CORRODED AREAS AT NUT PLATE HOLES T-CAP, BS 312 FLOOR BEAM BBL 0, RBL8. INSTALLED T-CAP REPAIR AND REPAIRED PER SRM 53-10-9. CORROSION TASK NRC53-107-02, CORROSION LEVEL 1. (M)