What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES FLOOR BEAM BS 344 BBL '0' TO LBL 43. INSTALLED NEW SECTION OF 'T' CAP, REPAIRED PER TR 53-10-3. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)