What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND TWO 2 INCH CRACKS SHEAR WEB BS 500 G PLUS 5 INCH AND BS 500 G PLUS 15 INCH AT RBL 45. FABRICATED NEW SHEAR WEB AND INSTALLED, REPAIRED PER BOEING DRAWING 69-35366. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND TWO 2 INCH CRACKS SHEAR WEB BS 500 G PLUS 5 INCH AND BS 500 G PLUS 15 INCH AT RBL 45. FABRICATED NEW SHEAR WEB AND INSTALLED, REPAIRED PER BOEING DRAWING 69-35366. (M)