What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER AREAS OF CORROSION STATION 947 FLOOR BEAM UPPER CHORD AT CLIP NUT HOLES. CUT OUT DAMAGED CAP SECTION AND SPLICED IN NEW SECTION PER EA 41312 AND SRM 53-00-51 FIG 202. REPAIRED PER EA 41312 SRM 53-00-51 FIG 202. CORROSION TASK NR C53-107-02. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)