What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND TWO .25 INCH CRACKS AT FASTENER HOLES STATION 532, STRINGER 15R. REMOVED DAMAGED SECTION OF STRINGER AND PERFORMED STRINGER SPLICE REPAIR. REPAIRED PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND TWO .25 INCH CRACKS AT FASTENER HOLES STATION 532, STRINGER 15R. REMOVED DAMAGED SECTION OF STRINGER AND PERFORMED STRINGER SPLICE REPAIR. REPAIRED PER SRM 53-10-3. (M)