What was found
CLT - INSPECTION VISUALLY FOUND 1 INCH BY 1 INCH CORROSION AREA, LOCATED AT STATION 312 FLOOR BEAM AT BL 0 RBL 24. FABRICATED AND INSTALLED T-CAP AS PER SRM AND TYPICAL REPAIR MANUAL 53-10-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION VISUALLY FOUND 1 INCH BY 1 INCH CORROSION AREA, LOCATED AT STATION 312 FLOOR BEAM AT BL 0 RBL 24. FABRICATED AND INSTALLED T-CAP AS PER SRM AND TYPICAL REPAIR MANUAL 53-10-03. (M)