What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1.25 INCH CRACK LBL 4.5 INCH STATION 178 PRESSURE BULKHEAD 6 INCHES BELOW FLOOR LEVEL. INSTALL FILLER AND DOUBLER, REPAIRED PER TR 53-10-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1.25 INCH CRACK LBL 4.5 INCH STATION 178 PRESSURE BULKHEAD 6 INCHES BELOW FLOOR LEVEL. INSTALL FILLER AND DOUBLER, REPAIRED PER TR 53-10-07. (M)