What was found
CLT - INSPECTION VISUALLY FOUND A .5 INCH BY 4 INCH LEVEL 2 CORRODED AREA, LOCATED AT FLOOR BEAM STATION NR 312, LBL 26. INSTALLED REPAIR ANGLES AS PER USAIR TYPICAL REPAIR 53-10-03. CORROSION TASK NR C53-107-02, CORRROSION LEVEL 2. (M)