What was found
CLT - INSPECTION VISUALLY FOUND A 1 INCH BY .5 INCH LEVEL 2 CORRODED AREA, LOCATED AT FLOOR BEAM STATION NR 344 LBL 22. INSTALLED REPAIR ANGLES PER USAIR TYPICAL REPAIR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION VISUALLY FOUND A 1 INCH BY .5 INCH LEVEL 2 CORRODED AREA, LOCATED AT FLOOR BEAM STATION NR 344 LBL 22. INSTALLED REPAIR ANGLES PER USAIR TYPICAL REPAIR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)