What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CRACKS APPROXIMATELY 1 INCH LONG IN VERTICAL WEB STATION 706 RBL 24. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CRACKS APPROXIMATELY 1 INCH LONG IN VERTICAL WEB STATION 706 RBL 24. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-2. (M)