As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 2 INCH CORRODED AREA STRINGER SPLICE BS 362 TO 363, STRINGER 27L. INSTALLED NEW SPLICE WITH 2 ADDITIONAL FASTENER ROWS, REPAIRED PER EA NR 41756. CORROSION TASK NR C53-202-01, CORROSION LEVEL 1. (M)