What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 3 INCH BY 3 INCH CORRODED AREA BS 1016 LBL 30 FLOOR PAN. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-70-13, FIG 1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 3 INCH BY 3 INCH CORRODED AREA BS 1016 LBL 30 FLOOR PAN. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-70-13, FIG 1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)