What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 3 INCH CORRODED AREA BS 500 D PLUS 2 INCHES STRINGER 28R. REMOVED CORRODED AREA INSTALLED REPAIR PARTS COMPLETED REPAIR, REPAIRED PER SRM 53-30-12 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 3 INCH CORRODED AREA BS 500 D PLUS 2 INCHES STRINGER 28R. REMOVED CORRODED AREA INSTALLED REPAIR PARTS COMPLETED REPAIR, REPAIRED PER SRM 53-30-12 FIG 202. (M)