What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH CRACKED BEAM RBL 24.5 BS 674. INSTALLED STIFFENER AND NEW CHANNEL, REPAIRED PER EO 5791G632. (M)