What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 6 INCH CORRODED AREA AFT CARGO BS 862-887, STRINGER 23R. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3 DETAIL 7 SH 8. CORROSION TASK NR C53-2002-01, CORROSION LEVEL 1. (M)