INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK BS 500B BETWEEN STRINGER 24R AND 23R FRAME SHEAR TIE. INSTALLED NEW SHEAR TIE WITH DOUBLER, REPAIRED PER SRM 53-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK BS 500B BETWEEN STRINGER 24R AND 23R FRAME SHEAR TIE. INSTALLED NEW SHEAR TIE WITH DOUBLER, REPAIRED PER SRM 53-10-4. (M)