What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 6 INCH BY 30 INCH CORROSION AT STATION 455 TO STATION 485 STRINGER 26L SKIN. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 6 INCH BY 30 INCH CORROSION AT STATION 455 TO STATION 485 STRINGER 26L SKIN. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3. (M)