What was found
ROA - DURING CX-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CORRODED AREA STRINGER SPLICE STATION 360, STRINGER 27L. REMOVED CORROSION AND INSTALLED NEW STRINGER SPLICE, C/C 1127803. REPAIRED PER SRM 51-10-6/51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ROA - DURING CX-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CORRODED AREA STRINGER SPLICE STATION 360, STRINGER 27L. REMOVED CORROSION AND INSTALLED NEW STRINGER SPLICE, C/C 1127803. REPAIRED PER SRM 51-10-6/51-30-2. (M)