What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STRINGER 16L AT STATION 500 C PLUS 4 INCH. INSTALLED DOUBLER PER EO 5343X228 PART 5, REPAIRED PER EO. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STRINGER 16L AT STATION 500 C PLUS 4 INCH. INSTALLED DOUBLER PER EO 5343X228 PART 5, REPAIRED PER EO. (M)