What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STRINGER 16R AT STATION 500C PLUS 4 INCH. INSTALLED DOUBLER PER EO 534X228. REPAIRED PER EO. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STRINGER 16R AT STATION 500C PLUS 4 INCH. INSTALLED DOUBLER PER EO 534X228. REPAIRED PER EO. (M)