What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 5 INCH CRACK IN WEB SKIN AT BS 695 STUB BEAM LBL 61, WL 205. INSTALLED WEB REPAIR, REPAIRED PER SRM 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 5 INCH CRACK IN WEB SKIN AT BS 695 STUB BEAM LBL 61, WL 205. INSTALLED WEB REPAIR, REPAIRED PER SRM 51-40-2. (M)