What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH CORRODED AREA BL 0 BS 628 STRINGER 1 SKIN. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH CORRODED AREA BL 0 BS 628 STRINGER 1 SKIN. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3. (M)