What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 3 INCH LONG CRACK STATION 695 LBL 61 INCH STUB BEAM WEB. CUTOUT DAMAGE AND INSTALLED REPAIR DOUBLER, REPAIRED PER SRM. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 3 INCH LONG CRACK STATION 695 LBL 61 INCH STUB BEAM WEB. CUTOUT DAMAGE AND INSTALLED REPAIR DOUBLER, REPAIRED PER SRM. (M)