What was found
CLT - DURING RON CHECK VISUAL/EDDY CURRENT INSPECTION, FOUND 3.5 INCH CRACK IN SKIN 1 INCH AFT OF STATION 727D EXTENDING AFT .5 INCH BELOW STRINGER 22R. INSTALLED EXTERNAL DOUBLER 10 INCH BY 16 INCH PER SRM 53-00-01 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING RON CHECK VISUAL/EDDY CURRENT INSPECTION, FOUND 3.5 INCH CRACK IN SKIN 1 INCH AFT OF STATION 727D EXTENDING AFT .5 INCH BELOW STRINGER 22R. INSTALLED EXTERNAL DOUBLER 10 INCH BY 16 INCH PER SRM 53-00-01 FIG 202. (M)