What was found
INT - DURING 'Q-3' CHECK VISUAL AND EDDY CURRENT INSPECTIONS, FOUND 2 INCH CRACKED FLOOR BEAM AT STA 520 RBL 24. INSTALLED REPAIR, REPAIRED PER SB 737-53-1120 AND EA 42226. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-3' CHECK VISUAL AND EDDY CURRENT INSPECTIONS, FOUND 2 INCH CRACKED FLOOR BEAM AT STA 520 RBL 24. INSTALLED REPAIR, REPAIRED PER SB 737-53-1120 AND EA 42226. (X)